Nominal Case

Specification • In the nominal case the close packet is immediately acknowledged by the receive TEP and the transmit TEP transitions to the CLOSED state. The receive TEP transitions to the CLOSED state after the expiration of its timer. The purpose of the receive TEP’s delay in the CLOSING state is to...

Communication Specification > SpaceWire > Protocols > JAS Reliable Data Delivery Protocol > Channel Operations > Channel Closing Process > Nominal Case

Obscuration

Specification • All JAS mechanical structure components shall be placed to prevent obscuration of the system view of space if the JAS electronics box will be used to radiate. Structural elements shall be kept an appropriate distance away from the JAS electronics housings.

Mechanical Specification > Design Constraints > Obscuration

Operating Temperatures

Specification • Operational temperatures are provided in thermal study for the nominal orbit. Excursions from predicted operational temperatures shall be increased by 11C (bilateral) when these temperatures are utilized in all fatigue analysis. For the purposes of fatigue the temperature excursion within an orbital season may be considered. For the purposes of...

Environmental Specification > Operating Temperatures

Packaging for Thermal Dissipation

Specification • The preliminary JAS mounting details are defined by the baseplate details in ICD drawing xxxxxx. The JAS electronics box is meant to mount through the blue baseplate shown in the figure below. The figure shows a nominal 3x3 stack in an exploded view. JAS Mounting Exploded View Conducted Self-radiated panels...

Mechanical Specification > Environmental Exposure > Packaging for Thermal Dissipation

Packet Addressing and Routing

Specification • Packets will be identified and routed in the system using the SAPID, DAPID, ST, and SST. Applications shall provide these fields to the JAS Packet Service to create the stream of packets that will be sent across the communication channel. Communication channels and addresses, such as a SpaceWire address, can...

Communication Specification > JAS Packets > JAS Packet Definition > Packet Addressing and Routing

Packet Error Control

Specification • Even though JAS network protocols offer a guaranteed delivery option, there still exists the possibility of an error being introduced into a packet while it is being created or transferred from memory to the communication channel. To provide an additional layer of error detection all JAS packets shall contain a...

Communication Specification > JAS Packets > JAS Packet Definition > Packet Error Control

Packet Sequencing

Specification • The use of the packet sequencing fields within the JAS packet is different from the definition in the CCSDS and PUS standards. The original intention of the packet sequence counter was to provide two functions. First, it was used in combination with the sequence flags to reassemble data sets that...

Communication Specification > JAS Packets > JAS Packet Definition > Packet Sequencing

Packet Service Definitions

Specification • [Placeholder: services reserved for and specific to JAS; this is a lead in to describe the services. Contact SNL if immediate support is needed with this topic. Content will be developed for JT 2.0.]

Communication Specification > JAS Packets > Packet Service Definitions

Particulate Contamination

Specification • Internal Cavities will be wiped clean with isopropyl alcohol and allowed to air dry for 30 minutes prior to close out; the structure will be covered during the drying process. The surfaces will be visibly clean. Visibly clean is defined as no contamination visible when viewed from 6-18 inches away...

Mechanical Specification > Design Constraints > Cleanliness > Particulate Contamination

Payload

Specification • JRDDP Packet Format Secondary Header (Optional) The presence of the optional secondary header is indicated by the Secondary Header Flag in the Packet Control field. If a secondary header is present, its contents and format are implementation dependent and shall be documented in a program specific document. The secondary header...

Communication Specification > SpaceWire > Protocols > JAS Reliable Data Delivery Protocol > JRDDP Packet Format > Payload

PCI Express

Specification • PCI Express, or PCIe, is another multi-lane high speed serial interconnect technology. Each lane is a full-duplex data stream comprised of two differential signaling pairs, one for transmitting and one for receiving.

Electrical Specification > Communication Data Links > PCI Express

Platform Management Service

Specification • The platform management service, service type address 130 is used to configure, manage, and monitor network specific resources. The currently defined platform management service parameters are shown in the following table. Service Type Service Subtype Subtype Description Cmd Tlm Service Parameters Data Types and Description 130 11 Network Topology Upload...

Communication Specification > JAS Packets > Packet Service Definitions > JAS Specific Services Definitions > Platform Management Service

Potential Flight Capability

Specification • Each component of the JAS mechanical structure should consider Flight capability as this will force consideration of design, flight, and test environments described in this specification. The JAS mechanical structure should be designed for the specific application intended.

Mechanical Specification > Mechanical Interface Design > Potential Flight Capability

Power Distribution Architecture

Specification • JAS will accept at least one primary input power source supplied to the system. The primary input power will connect directly to the Power Supply or PS node in a JAS arrangement. The PS node converts the primary input voltage to a lower voltage which is then sent to all...

Electrical Specification > Power Distribution Architecture

Pressure

Specification • The JAS structure shall meet all performance specifications during and after exposure to pressures varying from atmospheric to the space environment of 10-14 Torr. All thermal-vacuum ground based testing shall be conducted at pressures less than 10-6 Torr.

Environmental Specification > Pressure

Pressure Change

Specification • The structure shall be designed to survive the change of pressure specified in the figure below. The launch and ascent pressure environment will lie between Pc(Max) and Pc(MIN). Pressure Change Within the envelope defined in figure above, the local rates of change will remain between the values shown in the...

Environmental Specification > Pressure > Pressure Change