Search

Results 26–50 of 144

Device Access Service

Specification • The device access service, service type address 128, is used to request parameters from or command parameters to a specific device. The currently defined device access service parameters are shown in the following table. Service Type Service Subtype Subtype Description Cmd Tlm Service Parameters Data Types and Description 128 1...

Communication Specification > JAS Packets > Packet Service Definitions > JAS Specific Services Definitions > Device Access Service

ECSS Packet Utilization Standard

Specification • The figures below show a PUS telecommand and telemetry packet and their utilization within the CCSDS space packet specification. The PUS specification uses the user-definable fields of the CCSDS space packet in order to create a PUS packet. The specification defines a secondary header that provides additional metadata such as...

Communication Specification > JAS Packets > ECSS Packet Utilization Standard

Electrical Bonding

Specification • Each equipment design shall provide electrical continuity across mechanical interfaces in accordance with the design requirements of this specification. Electrical continuity will be achieved to the maximum practical extent by direct metal-to-metal contact across the entire interface surface. If the electrical resistance across mechanical interfaces is measured to be less...

Mechanical Specification > Environmental Exposure > Electromagnetic Compatibility > Electrical Bonding

Electrical Interconnects

Specification • JAS electrical design shall utilize commercial interconnect standards when applicable. The following sections are some examples of commercial interconnect standards that are recommended but not required.

Electrical Specification > Electrical Interconnects

Electrical Specification

Specification • The Electrical Specification provides details about power distribution, electrical interconnects, and communication data links that are used within a JAS-based system. The figure below provides context of where the Electrical Specification resides in the JAS standard. JAS Standard Hierarchy

Electrical Specification

Electromagnetic Compatibility

Specification • Electromagnetic Interference (EMI) and Electromagnetic Compatibility (EMC) are important design considerations which can be mitigated by the mechanical structure. EMI limits may be in place due to application-specific requirements, but more importantly, EMI can be detrimental to electronics because of the sensitive nature of many of the modern systems and...

Mechanical Specification > Environmental Exposure > Electromagnetic Compatibility

Environmental Exposure

Specification • Unless otherwise specified, the JAS mechanical structure shall meet these specifications during or after exposure to all environmental conditions specified in the Environmental specification. All of the intended application’s performance parameters must be considered to determine if the mechanical design can withstand the impacts of all environments.

Mechanical Specification > Environmental Exposure

Environmental Specification

Specification • The Environmental Specification provides details about environmental design considerations that should be considered for space applications of JAS. The figure below provides context of where the Environmental Specification resides in the JAS standard. JAS Standard Hierarchy

Environmental Specification

Environmental Test Flow

Specification • Programs using JAS should practice testing per industry standards wherever possible. The following tests and operational environments shall be applied to the components or structure in the following order. Events 1 through 5 shall be used for qualification acceptance testing. Events 1-6 shall be considered for fatigue calculations. 1) 24ea,...

Environmental Specification > Environmental Test Flow

Ethernet

Specification • Ethernet comprises a family of networking technologies with numerous media types and standards; 100Base-T (IEEE 802.3-2008:section 8) and 1000Base-T (IEEE 802.3-2008:section 40) the most popular in use today.

Electrical Specification > Communication Data Links > Ethernet

Exposure to Space Environment

Specification • This section is a system level consideration and is included for information purposes only. The view to space shall be considered for both thermal and radiation effects. Thermal-related issue: heat-dissipation Radiation-related: TID (lifetime), SEE, shielding and impact on mass

Mechanical Specification > Environmental Exposure > Exposure to Space Environment

Factors of Safety

Specification • The JAS mechanical structure shall have strength margins of safety greater than zero when calculated from analytically derived structural loads. The factors of safety (FS), shown in the first table below, and test load factors, shown in the second table below, shall be applied to the limit loads. All laminated...

Mechanical Specification > Design Constraints > Structural Integrity > Factors of Safety

Fatigue

Specification • The JAS mechanical structure metallic elements shall be designed to withstand the effects of cyclic load condition caused by the design environment. The design environment includes all ground handling transportation, testing, launch and on orbit operational environments indicated in the Environmental Specification. MSFC-HDBK-505 Chapter 7 shall be implemented for fatigue...

Mechanical Specification > Design Constraints > Structural Integrity > Fatigue

Form Factor

Specification • While no specific form factor standard is specified in JAS it is highly recommended that programs make use of a standards-based mechanical design such as VPX defined by VITA. Although VPX is preferred, other standards may be considered for use as well. The consideration of alternate standards should carefully consider...

Mechanical Specification > Mechanical Interface Design > Form Factor

Grounding

Specification • Grounding provisions are required for the mechanical design to eliminate the potential for ESD charging on floating metal. Any component members with surface areas greater than 20 cm2 shall have a grounding provision. Bolted fittings are acceptable as grounding provisions if the joint meets the electrical resistance requirement for bonding....

Mechanical Specification > Environmental Exposure > Electromagnetic Compatibility > Grounding

Humidity

Specification • The JAS housing shall meet all performance specifications during exposure to relative humidity varying from 0% to 60%.

Environmental Specification > Humidity

Humidity Impact

Specification • The JAS mechanical structure shall maintain the electronics/PCBs within given displacements as applied by determining humidity impacts on the mechanical structure. If composite structures are used, the humidity should remain between a saturated composite at nominal 60% RH test area and a dry composite at 0% RH humidity vacuum environment...

Mechanical Specification > Environmental Exposure > Humidity Impact

Results 26–50 of 144